Armaflex Pipe Insulation for Air Conditioning

From the catalogue record

Armaflex AC pipe insulation for condensation control and energy efficiency. Select Class 0, Class 1 or FRV, insulation thickness and inner diameter to suit the pipe. Each tube is 2 m long.

Saved product details

These are the family record details. Check the selected variant and configuration for the specification you need.

Spesifikasi Armaflex — Merek
Armacell Armaflex
Spesifikasi Armaflex — Material
Karet elastomerik sel tertutup (NBR)
Spesifikasi Armaflex — Bentuk
Pipa / tubing
Spesifikasi Armaflex — Seri
Class 0, Class 1, FRV
Spesifikasi Armaflex — Panjang
2 m
Spesifikasi Armaflex — Ketebalan nominal
6, 9, 13, 19, 25, 32, 38, 40, 50 mm sesuai seri

Understand Armaflex pipe insulation

Armaflex pipe is tubular insulation fitted around a pipe. Match its bore, thickness and series to the requirements of your installation.

Where this product is used

Use it on air-conditioning pipe runs and other pipework requiring insulation under the system design. The tubular form helps match the insulation to the pipe size.

Record bends, branches, valves and supports too. These need installation details, not just an allowance for additional straight pipe.

How to choose a size

  • Start with the outside pipe diameter, measured across its outer surface. Match this to the insulation bore or inside diameter.
  • Select Class 0, Class 1 or FRV against the project documents, then choose a listed thickness and size using the product controls.
  • Record run length, joint count and installation location. Confirm the product unit before calculating the order quantity.

Terms in plain language

  • Inside diameter, or bore, is the size of the hole through the insulation. It is not the wall thickness.
  • Thickness is the material around the pipe. Select it from the system design, not pipe size alone.
  • Condensation means water droplets forming on a surface. Temperature, surrounding air and joint details all matter; insulation does not guarantee a dry surface in every condition.
Read detailed selection and installation guidance

Choose Armaflex pipe insulation

Armaflex Pipe Insulation for Air Conditioning: Pipe insulation follows the pipe run. Match the insulation bore to the outside pipe diameter; select thickness from the design and operating conditions rather than diameter alone.

Application and selection

Record straight runs, elbows, branches, valves and supports. These need planned cuts and joints so the insulation is not interrupted at difficult access points.

Limits to check

Treat Class 0, Class 1, FRV and foil configurations as separate choices where recorded. Do not stretch insulation to force a fit or assume tape replaces the full joint bonding procedure.

Before requesting a quotation

  • Measure the outside pipe diameter and record its units.
  • Record the series, design thickness, run length and fitting quantities.
  • Check joints, supports and protection for exposed areas.

Separate diameter, thickness and length

A nominal pipe designation names a size; it does not guarantee the same outside diameter across pipe types. Record the pipe material and actual outside diameter or the measurement from its pipe documentation. If a list mixes inches and millimetres, retain the original units and reference rather than treating similar numbers as equivalent.

The insulation bore receives the pipe; thickness is the layer around it. They are not the same dimension field. Length per unit is also separate from total run length, so determine purchase quantities after confirming the product unit.

Review interruptions in the insulation layer

Supports, valves, joints and equipment connections need individual details. List these points rather than only metres of straight pipe. The detail needs to allow installation without unplanned gaps and account for reopening during servicing.

A photograph of visible thickness cannot establish the cause of condensation. Include operating conditions, the problem location and joint condition so the review is not limited to changing size.

Record the pipe configuration for consultation

In the product controls, choose the variant or series first, then the available thickness configuration and size option. Copy the full label, SKU where listed and unit into your requirements. If the design size is absent, ask about a suitable choice rather than changing diameter or substituting Class 0, Class 1 and FRV yourself.

Questions for this selection

Which pipe measurement should I provide?

Provide the outside pipe diameter, not just the nominal pipe designation. Match it to the insulation bore in the selected configuration.

Does a larger pipe always need thicker insulation?

Diameter alone does not determine thickness. Operating temperature, surrounding conditions and the system design calculation also matter.

How should elbows and valves be allowed for?

Record fitting shapes, quantities and working clearance. Discuss cutting patterns, material allowances and joints using the chosen series installation instructions.

What if the pipe list uses inches but the configuration uses millimetres?

Include the original dimension, units and pipe-type reference. Verify the outside diameter correspondence before choosing; do not round to the nearest option or equate a nominal designation with the actual measurement.

Will changing series alone solve condensation at a joint?

That cannot be guaranteed. Joints, supports, design thickness and operating conditions need review together; a series choice does not replace checking installation details.

This guide supports product selection. Use the selected configuration, current manufacturer instructions and approved project documents for technical decisions.