Armaflex Sheet Insulation for Ducting
From the catalogue record
Armaflex sheet and roll insulation for ducting, vessels and HVAC equipment surfaces. Choose the listed series, thickness, width and length combination. A 19 mm Class 0 core with aluminium foil and adhesive is also listed.
Saved product details
These are the family record details. Check the selected variant and configuration for the specification you need.
- Spesifikasi Armaflex — Merek
- Armacell Armaflex
- Spesifikasi Armaflex — Material
- Karet elastomerik sel tertutup (NBR)
- Spesifikasi Armaflex — Bentuk
- Roll / lembaran
- Spesifikasi Armaflex — Seri
- Class 0, Class 1, FRV
- Spesifikasi Armaflex — Ketebalan
- 6–50 mm sesuai seri dan bentuk
- Spesifikasi Armaflex — Batas suhu direkatkan penuh
- +85°C
Understand Armaflex sheet insulation
Armaflex sheet is insulation supplied as sheets or rolls that can be cut to fit ducts, vessels and equipment surfaces.
When to choose sheet
Sheet supports cutting patterns for flat, broad or curved surfaces. It differs from pipe insulation, which is already tubular.
Identify the surfaces to cover and the areas that need to open for inspection. Total area alone does not describe cutting patterns or joint quantities.
How to choose a sheet
- Choose the required series, then review thickness and the listed width-and-length combination in the product controls.
- If aluminium foil or an adhesive backing is required, select a configuration explicitly listing it. Do not assume every sheet has the same facing.
- Provide measurements for each surface, corners and service openings. Plan the cuts before deciding the number of sheets or rolls.
Terms in plain language
- Ducting carries air. Measure every surface included in the work, not only the front face.
- Facing means a surface layer, such as aluminium foil. It does not automatically permit outdoor use without other protection.
- Material thickness is separate from roll width and length. Check all three against the selected configuration.
Read detailed selection and installation guidance
Plan sheet insulation
Armaflex Sheet Insulation for Ducting: Armaflex sheet can be cut to follow duct and equipment surfaces. Measure net area, perimeter and shape changes rather than estimating sheet requirements from one side length.
Application and selection
Plan cuts for flat faces, corners and curved sections. Decide joint positions and service access before calculating sheet and adhesive quantities.
Limits to check
Recorded Class 0, Class 1, FRV and foil options need their own specification checks. Foil alone does not establish weather resistance or whole-assembly suitability; joints and protection still require design.
Before requesting a quotation
- Record surface dimensions and the designer-specified thickness.
- Separate net area from cutting and joint allowances.
- Check series, facing, sheet dimensions and installation access.
Measure surfaces before laying out cuts
For ducts, record each face and the length being covered. For curved equipment bodies, provide circumference measurements or a shape drawing. Pack dimensions, material thickness and working surface area are different information; one length does not represent them all.
Lay out the pieces before assigning an allowance. Inspection openings, corner joints and section changes can alter the cutting pattern and seam locations. Distinguish offcuts usable elsewhere from the need for new material.
Edges need as much planning as the main surface
Plan the junctions at flanges, panel edges, pipe entries and equipment mounts. These determine adhesive access and insulation continuity; surface area alone does not provide joint count or length.
Record the condition of paint or other coatings for preparation and adhesive compatibility review. Do not assume a foil option resolves edge details or replaces protection specified by the designer.
Read the sheet options on this page
Select the series or variant before checking configuration and size. Review the technical reference associated with the active choice; do not order from the dimension image of another option. Include the facing label where listed so a foil selection is not confused with other sheets.
Questions for this selection
Is the measured area the same as the order quantity?
Not always. Cutting patterns, corners, joints and equipment shapes can require extra material. Build the list from drawings or site measurements.
Can sheet replace pipe insulation on every pipe?
Do not assume an automatic substitution. Pipe shape, diameter, access and installation method determine whether sheet is appropriate for that section.
When should I choose a foil configuration?
Follow the facing requirement in the project specification, then check the configuration and its installation instructions. Facing colour does not establish a class or application limit.
Should sheet requirements be measured only from the front duct face?
No. Record every surface actually being covered, including shape changes and openings. Match measurements to the work scope so untreated surfaces are not included.
How should sheet be planned around an inspection panel?
Mark the panel boundary and opening requirements. Discuss separate pieces and reinstatement details so service access is not simply covered by one sheet.
This guide supports product selection. Use the selected configuration, current manufacturer instructions and approved project documents for technical decisions.